UE-01.S /SV-01.S
Monitoring unit
with voltage supply
The UE-01.S/SV-01.S monitoring device is used for simple monitoring of machines and system components.
The operating temperature range corresponds to temperature class T1/EN 50155. The circuit board is painted on both sides in accordance with EN 50155.
The device has a monitored signaling circuit and a monitored trigger circuit for the extinguishing agents.
The equipment includes unmonitored potential-free changeover contacts for alarm and fault messages as well as internal monitoring for the operating voltage. The fault message is issued when Ub < 18 VDC.
The monitoring device is compatible with all BRANDTRONIK detectors and a large number of third-party products using two-wire technology.
The extinguishing output can be deactivated. This process is indicated by an LED on the front panel, just like the operation, detector fault, extinguishing output fault, alarm and extinguishing functions. The reset button for resetting the device and detector is also located here.
All external components can be connected via plug-in spring-loaded terminals. The external power supply SV-01.S enables power supply in the range 90-264 V~/230 mA via a wide-range input.
The housing can be easily mounted on a standard rail.
UE-01.S /SV-01.S – data and facts
Monitoring device UE-01.S
| Operating voltage |
18…30 VDC
|
| Operating current |
30 mA
|
| Detector line Short circuit area Alarm area Operating area Interruption area Line voltage without RE |
1x monitored 0…120 Ω 180…900 Ω 1,5…7 kΩ > 10 kΩ 27 VDC |
| Output tripping Short circuit range Operating range Interruption range Monitoring current |
1x monitored 0…15 Ω 25…1 KΩ > 2,5 kΩ 5 mA |
| fault | @Ub < 18 VDC |
| Protection class of the housing | IP20 |
| Temperature range |
-25…+70° C
|
| Dimensions with plugs | 22.6x105x69.5 mm |
| Weight with plugs | 90 g |
| Mounting | standard rail DIN 46277 |
| Relay outputs Fault Alarm Not “monitored” means it is not a “primary line” and therefore the line is not checked for “open circuit” and “short circuit”. |
2 x not monitored one potential-free changeover contact each 30 VDC / 0.5 A |
| Terminal resistor for extinguishing output Rend (can be switched on) | 1 KΩ |
| Control elements | RESET, Rend ON |
Power supply SV-01.S
| Input voltage |
90…264 VAC
|
| Output voltage |
24 VDC ±2%
|
| Output current Protection class of the housing Temperature range Residual ripple Output power Power derating Dimensions with connectors |
< 230 mA
IP20
-25…+70° C
< 20 mVss
max. 5 W
@ Ta > 50° C 0,185 W/K
22,6 x 105 x 69,5 mm
|
These products might be interesting for you
UV-
FALME DETECTOR
Ultraviolet flame detectors detect both open flame and arc fires and are particularly suitable for use in potentially explosive atmospheres.
IR-
FALME DETECTOR
The infrared flame detector detects open flames and fires of both organic and inorganic materials and is well suited to flame detection.
UV-
SPARK DETECTOR
The infrared spark detector detects sparks and flames in closed systems, such as absolutely dark system parts with very little extraneous light incidence.
IR/UV-COMBI-FLAME DETECTOR
The IR/UV combination flame detector detects fires with an open flame involving carbon. This is well suited for open flames without smoke development.