This unit has been developed at lowest cost and effort for danger monitoring of machines and plant units.
It is equipped with an evaluation system and monitoring of a signalling circuit and includes triggering and monitoring of a means of alarm.
The device is built into a socket housing and may be affixed to a normed rail DIN 46277. Very suitable device for installation in control cabinets.
Key data:
Operating voltage 24 VDC
Operating current 50 mA
Ingress protection IP 20
UE-01.24
Pluggable monitoring unit with base, operating voltage 24 VDC
Price upon request.
SV-01.24
Pluggable current supply with base, 24 V / 100 mA suitable for UE-01.24
Price upon request.
UE-02
UE-02
Extinguishing System Control Unit
This device is equipped with a single-area extinguishing system control unit. Two monitored detection lines and a monitored equipment line form
the entry unit for alarm signals and fault warning.
Equally monitored are output part, acoustic triggering and triggering of extinguishing system.
The control unit features potential-free switches for fault, alarm and system-off.
Integrated DIP switches provide for different time delays and detection line combinations. An extinguishing trigger time range may be configured.
A 24 V / 0,8 Ah emergency power battery may be installed in the case.
Key data:
Ingress protection IP 65
Operating voltage 230 VAC or 24V DC / 1A
Housing dimensions 230 x 185 x 120 mm
UE-02
Single area low-voltage extinguishing system control, Power supply 24VDC / 1A
Price upon request.
Exclusive of door lock and battery.
UE-03
UE-03 with connecting plugs
UE-03
Extinguishing System Control Unit
This single area extinguishing system control features three monitored signalling circuits for Detectors, manual release and monitored outputs for acoustics and extinguishing triggering.
In addition, the unit is equipped with potential-free toggles for faults, pre-alarm, system-off and potential-free 230 VAC change-over switches for pre-alarm and alarm, respectively.
Two-line dependency and alarm buffer memory may be connected.
Extinguishing triggering may be delayed and limited by different settings.
A 24 V / 2.1 Ah emergency battery may be installed in the housing.
Key data:
Ingress protection IP 65
Voltage:
110 VAC / 230 VAC oder 24 VDC
/ 2 A
or
400 VAC
Housing dimensions
285 x 215 x 145 mm
Plug
version
UE-03 Extinguishing system control unit with connecting plugs
The signal output makes the difference between the plug version and the version described above.
Signalling circuits, acoustics, extinguishing triggering and potential-free toggles for alarm, faults and system-off are designed as plug contacts.
UE-03
Single area extinguishing system control unit, current supply 24 DC /2 A
Price upon request.
Including door lock and exclusive of battery.
FU-01
FU-01
Spark Extinguishing System Control
This single area spark extinguishing system control unit is equipped with two monitored signalling circuits for spark Detectors and monitoring of extinguishing agent.
Outputs for acoustics and extinguishing time triggering are monitored.
The device features potential-free toggles for faults, alarm and production plant-off.
DIP switches provide individual adjustment for alarm counters and switch-off of production plant.
A 24 V / 0.8 Ah emergency battery may be installed in the housing.
Key data:
Ingress protection IP65
Voltage supply 230 VAC or 24 VDC / 1A
Housing dimensions 240 x 185 x 120 mm
FU-01
Single area spark extinguishing control unit, current supply 24 VDC / 1 A